Ozone Amperometric Sensors |
• Amperometirc Dual Electrode System with Replacement Membranes.
• Gold Cathode, Silver/Silver Halogenid Anode.
• Temperature Range 45ºC
|
|
|
|
|
Chlorine Dioxide Amperometric Sensors |
With the exception of the 4-20mA sensors, where the length is 220mm, the sensors have a length of 175mm and a diameter of 25mm, with plug adaptor connection.
They are designed to fit into the available flow cells.
The low current produced by the sensors is electronically amplified in the measurement cell.
No zero point calibration is necessary, and measurements can be taken in pressure up to 1 BAR.
The sensors are temperature compensated, and will operate in the range 0 to 45 degrees C (for the 8 Series, 0-55).
The water has to be flowing to obtain a reading, which is why flow cells are recommended.
Changes to the minimum flow rate will only slightly affect the measurement signal.
Surfactants should not be present in the water being measured (does not apply to the 8 Series probes).
For the dual electrode system, the measurement cell is made of gold, and the counter and reference electrodes of silver with silver halogenid coating.
A bias voltage (polarisation) is applied between the two electrodes.
For the potentiostatic 3 electrode system, the measurement electrode is made of gold, the reference electrode is made of silver with a silver halogenid coating, and the counter electrode of stainless steel.
|
|
|
|
|
Dissolved Chlorine Di Oxide Sensors |
With the exception of the 4-20mA sensors, where the length is 220mm, the sensors have a length of 175mm and a diameter of 25mm, with plug adaptor connection.
They are designed to fit into the available flow cells.
The low current produced by the sensors is electronically amplified in the measurement cell.
No zero point calibration is necessary, and measurements can be taken in pressure up to 1 BAR.
The sensors are temperature compensated, and will operate in the range 0 to 45 degrees C (for the 7 Series, 0-55).
The water has to be flowing to obtain a reading, which is why flow cells are recommended.
Changes to the minimum flow rate will only slightly affect the measurement signal.
Surfactants should not be present in the water being measured (does not apply to the 7 Series probes).
For the dual electrode system, the measurement cell is made of gold, and the counter and reference electrodes of silver with silver halogenid coating. A bias voltage (polarisation) is applied between the two electrodes.
For the potentiostatic 3 electrode system, the measurement electrode is made of gold, the reference electrode is made of silver with a silver halogenid coating, and the counter electrode of stainless steel.
|
|
|
|
|
Oxygen Sensor |
Description / Specification of Oxygen Sensor |
We are involved in offering a wide range of Oxygen Sensor to our most valued clients. Our range of these are widely appreciated by our clients which are situated all round the nation. We offer our range of it at most affordable prices.
We introduce ourselves as an eminent trader and supplier of an extensive array of Oxygen Sensor. Prior to dispatch, our quality controllers run numerous tests on the entire range on various parameters of quality and durability. The offered equipment is manufactured using superior quality components with the aid of sophisticated techniques at the vendors' end. Moreover, our precious clients can purchase it in different technical specifications at reasonable price from us within promised time frame.
Features:
- Sturdy design
- Highly durable
- Application specific design
|
|
|
|
|
|
|
|
|
|
|
|